ABB Contactor AF460-30-11-70 Coil Voltage: 100-250 VDC

00632/3T

General Information

Extended Product Type:

AF460-30-11-70

Product ID:

1SFL597001R7011

EAN:

7320500217658

Catalog Description:

AF460-30-11 100-250V 50/60Hz / 100-250V DC Contactor

 

Dimensions

Product Net Width:

186 mm

Product Net Depth / Length:

216 mm

Product Net Height:

278 mm

Product Net Weight:

10.6 kg

Technical

Number of Main Contacts NO:

3

Number of Main Contacts NC:

0

Number of Auxiliary Contacts NO:

1

Number of Auxiliary Contacts NC:

1

Rated Operational Voltage:

Main Circuit 1000 V

Rated Frequency (f):

Main Circuit 50 / 60 Hz

Conventional Free-air Thermal Current (Ith):

acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 700 A

Rated Operational Current AC-1 (Ie):

(1000 V) 40 °C 700 A

(1000 V) 55 °C 600 A

(1000 V) 60 °C 600 A

(1000 V) 70 °C 480 A

(690 V) 40 °C 700 A

(690 V) 55 °C 600 A

(690 V) 70 °C 480 A

Rated Operational Current AC-3 (Ie):

(415 V) 55 °C 460 A

(440 V) 55 °C 460 A

(500 V) 55 °C 460 A

(690 V) 55 °C 400 A

(1000 V) 55 °C 200 A

(380 / 400 V) 55 °C 460 A

(220 / 230 / 240 V) 55 °C 460 A

Rated Operational Power AC-3 (Pe):

(415 V) 250 kW

(440 V) 250 kW

(500 V) 315 kW

(690 V) 355 kW

(1000 V) 280 kW

(380 / 400 V) 250 kW

(220 / 230 / 240 V) 132 kW

Rated Breaking Capacity AC-3:

8 x Ie AC-3

Rated Making Capacity AC-3:

10 x Ie AC-3

Short-Circuit Protective Devices:

gG Type Fuses 800 A

Rated Short-time Withstand Current Low Voltage (Icw):

at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 4400 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 840 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2500 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4600 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3100 A

Maximum Breaking Capacity:

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4500 A

Maximum Electrical Switching Frequency:

(AC-1) 300 cycles per hour

(AC-2 / AC-4) 60 cycles per hour

(AC-3) 300 cycles per hour

Rated Operational Current DC-1 (Ie):

(110 V) 1-Pole, 40 °C 700 A

(110 V) 2 Poles in Series, 40 °C 700 A

(220 V) 3 Poles in Series, 40 °C 700 A

(600 V) 3 Poles in Series, 40 °C 700 A

Rated Operational Current DC-3 (Ie):

(110 V) 1-Pole, 40 °C 700 A

(110 V) 2 Poles in Series, 40 °C 700 A

(220 V) 3 Poles in Series, 40 °C 700 A

(600 V) 3 Poles in Series, 40 °C 700 A

Rated Operational Current DC-5 (Ie):

(110 V) 1-Pole, 40 °C 700 A

(110 V) 2 Poles in Series, 40 °C 700 A

(220 V) 3 Poles in Series, 40 °C 700 A

(600 V) 3 Poles in Series, 40 °C 700 A

Rated Insulation Voltage (Ui):

acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V

acc. to UL/CSA 600 V

Rated Impulse Withstand Voltage (Uimp):

Main Circuit 8 kV

Mechanical Durability:

3 million

Maximum Mechanical Switching Frequency:

300 cycles per hour

Coil Operating Limits:

(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)

Rated Control Circuit Voltage (Uc):

50 Hz 100 ... 250 V

60 Hz 100 ... 250 V

DC Operation 100 ... 250 V

Coil Consumption:

Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A

Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A

Holding at Max. Rated Control Circuit Voltage DC 5 V·A

Pull-in at Max. Rated Control Circuit Voltage 50 Hz 955 V·A

Pull-in at Max. Rated Control Circuit Voltage 60 Hz 955 V·A

Pull-in at Max. Rated Control Circuit Voltage DC 895 V·A

Operate Time:

Between Coil De-energization and NC Contact Closing 45 ... 55 ms

Between Coil De-energization and NO Contact Opening 48 ... 58 ms

Between Coil Energization and NC Contact Opening 45 ... 115 ms

Between Coil Energization and NO Contact Closing 50 ... 120 ms

Connecting Capacity Main Circuit:

Bar 47 mm²

Rigid Al-Cable 2x240 mm²

Rigid Cu-Cable 240 mm²

Connecting Capacity Auxiliary Circuit:

Flexible with Ferrule 2x 0.75 ... 2.5 mm²

Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²

Flexible 2x0.75 ... 2.5 mm²

Solid 2 x 1 ... 4 mm²

Stranded 2 x 1 .... 4 mm²

Degree of Protection:

acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00

Terminal Type:

Main Circuit: Bars

Technical UL/CSA

NEMA Size:

6

Horsepower Rating NEMA:

(200 V AC) Three Phase 150 Hp

(230 V AC) Three Phase 200 Hp

(460 V AC) Three Phase 400 Hp

(575 V AC) Three Phase 400 Hp

Maximum Operating Voltage UL/CSA:

Main Circuit 1000 V

General Use Rating UL/CSA:

(600 V AC) 650 A

Horsepower Rating UL/CSA:

(200 V AC) Three Phase 150 hp

(208 V AC) Three Phase 150 hp

(220 ... 240 V AC) Three Phase 200 hp

(440 ... 480 V AC) Three Phase 400 hp

(550 ... 600 V AC) Three Phase 500 hp