rig-well.com

Weidmuller WAS5 PRO RTD Transformer 8560700000

RTD isolating transformer, 2-/3-/4- wire RTD, Configurable, Input : Temperature, PT100, Output : 0(4)-20 mA, 0-10 V
SKU: RWHD229U1Z2407
General ordering data
Version RTD isolating transformer, 2-/3-/4- wire RTD, Configurable, Input : Temperature, PT100, Output : 0(4)-20 mA, 0-10 V
Order No. 8560700000
Type WAS5 PRO RTD
GTIN (EAN) 4032248207312
Qty. 1 pc(s).
Available until 2022-03-30
Alternative product 1176030000
Dimensions and weights
Depth 112.4 mm
Depth (inches) 4.425 inch
Width 17.5 mm
Width (inches) 0.689 inch
Length 92.4 mm
Length (inches) 3.638 inch
Net weight 138 g
Temperatures
Storage temperature -20 °C…85 °C
Operating temperature 0 °C…55 °C
Probability of failure
MTTF 270 a
Environmental Product Compliance
REACH SVHC Lead 7439-92-1
SCIP b25f3b7c-b874-4a4e-a8b2-4f423a7e2a65
RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 6c, 7a, 7cI
Input
Line resistance in measuring circuit 50 Ω for 3- and 4-conductor
Number of inputs 1
Sensor PT100 (2-/3-/4- wire)
Temperature input range Configurable, PT100: -200°C…850 °C, NI100: -60°C…+250 °C
Output
Fine adjustment ≥ ± 5 %, Version 1 and later: ≥ 12.5 % / potentiometer: 12.5%…25%
Load impedance current ≤ 600 Ω
Number of outputs 1
Offset current max. 100 µA
Offset voltage max. 0.05 V
Output current 0…20 mA, 4…20 mA
Output voltage, note 0…10 V
Wire break detection LED flashing (output value: > 20 mA, >10 V)
load impedance voltage ≥ 1 kΩ
Output (digital)
Status indicator Module active: LED on/ wire breakage: LED flashing/Error: LED off
General data
Accuracy < 0.3 % of measured value
Configuration DIP switch, Potentiometer
Galvanic isolation 3-way isolator
Linearity Yes
Power consumption 830…880…980 mW at IOUT = 20 mA
Protection degree IP20
Rail TS 35
Step response time fast/slow: 2-/3-/4-conductor: 1.2 s/2.2 s; potentiometer: 0.5 s/1.1 s
Temperature coefficient
Insulation coordination
EMC standards EN 55011, EN 61000-6
Galvanic isolation 3-way isolator
Impulse withstand voltage 4 kV
Insulation voltage 2 kVeff / 5 s
Insulation voltage input or output/rail 4 kVeff / 1 min.
Insulation voltage input or output/supply 2 kVeff / 5 s
Pollution severity 2
Rated voltage 300 V
Surge voltage category III
Connection data
Type of connection Screw connection
Stripping length, rated connection 7 mm
Tightening torque, min. 0.4 Nm
Tightening torque, max. 0.5 Nm
Clamping range, rated connection 2.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, max. 2.5 mm²
Weight 0.15 kg
error: