| Pulses per revolution | 2,500 |
| Measuring step | 90°, electric/pulses per revolution |
| Measuring step deviation | ± 18° / pulses per revolution |
| Error limits | ± 54° / pulses per revolution |
| Duty cycle | ≤ 0.5 ± 5 % |
| Communication interface | Incremental |
| Communication Interface detail | TTL / RS-422 |
| Number of signal channels | 6-channel |
| Initialization time | < 3 ms |
| Output frequency | ≤ 300 kHz |
| Load current | ≤ 30 mA |
| Operating current | ≤ 50 mA (without load) |
| Connection type | Cable, 8-wire, universal, 0.5 m |
| Supply voltage | 4.5 … 5.5 V |
| Reference signal, number | 1 |
| Reference signal, position | 90°, electric, logically gated with A and B |
| Mechanical design | Blind hollow shaft |
| Shaft diameter | 8 mm Front clamp 1) |
| Weight | + 150 g (with connecting cable) |
| Shaft material | Stainless steel |
| Flange material | Aluminum |
| Housing material | Aluminum |
| Material, cable | PVC |
| Start up torque | + 0.5 Ncm (+20 °C) |
| Operating torque | 0.4 Ncm (+20 °C) |
| Permissible movement static | ± 0.3 mm (radial)
± 0.5 mm (axial) 2) |
| Permissible movement dynamic | ± 0.1 mm (radial)
± 0.2 mm (axial) 2) |
| Operating speed | 6,000 min⁻¹ 3) |
| Maximum operating speed | ≤ 8,000 min⁻¹ 4) |
| Moment of inertia of the rotor | 0.8 gcm² |
| Bearing lifetime | 2 x 10^9 revolutions |
| Angular acceleration | ≤ 500,000 rad/s² |
| EMC | According to EN 61000-6-2 and EN 61000-6-3 (class A) |
| Enclosure rating | IP65 |
| Permissible relative humidity | 90 % (Condensation not permitted) |
| Operating temperature range | –20 °C … +85 °C, –35 °C … +95 °C on request |
| Storage temperature range | –40 °C … +100 °C, without package |
| Resistance to shocks | 100 g, 6 ms (EN 60068-2-27) |
| Resistance to vibration | 20 g, 10 Hz … 2,000 Hz (EN 60068-2-6) |