| Range of Product | Harmony Safety Automation |
|---|---|
| Product or Component Type | Safety module |
| Safety module name | XPSBAC |
| Safety module application | For emergency stop and protective guard applications |
| Function of module | Emergency stop button with 2 NC contacts Guard monitoring with 1 or 2 limit switches |
| Safety level | Can reach PL e/category 4 for normally open relay contact ISO 13849-1 Can reach SILCL 3 for normally open relay contact IEC 62061 Can reach SIL 3 for normally open relay contact IEC 61508 Can reach PL c/category 1 for normally closed relay contact ISO 13849-1 Can reach SILCL 1 for normally closed relay contact IEC 62061 Can reach SIL 1 for normally closed relay contact IEC 61508 |
| Safety reliability data | MTTFd > 30 years for normally open relay contact ISO 13849-1 Dcavg >= 99 % for normally open relay contact ISO 13849-1 PFHd = 1.01E-09 for normally open relay contact ISO 13849-1 HFT = 1 for normally open relay contact IEC 62061 PFHd = 1.01E-09 for normally open relay contact IEC 62061 SFF > 99% for normally open relay contact IEC 62061 HFT = 1 for normally open relay contact IEC 61508-1 PFHd = 1.01E-09 for normally open relay contact IEC 61508-1 SFF > 99% for normally open relay contact IEC 61508-1 Type = B for normally open relay contact IEC 61508-1 MTTFd > 30 years for normally closed relay contact ISO 13849-1 DC > 60 % for normally closed relay contact ISO 13849-1 PFHd = 1.01E-09 for normally closed relay contact ISO 13849-1 HFT=0 for normally closed relay contact IEC 62061 PFHd = 1.01E-09 for normally closed relay contact IEC 62061 SFF > 60% for normally closed relay contact IEC 62061 HFT=0 for normally closed relay contact IEC 61508-1 PFHd = 1.01E-09 for normally closed relay contact IEC 61508-1 SFF > 60% for normally closed relay contact IEC 61508-1 Type = B for normally closed relay contact IEC 61508-1 |
| Electrical circuit type | NC pair |
| Connections – terminals | Removable screw terminal block, 0.2…2.5 mm² solid or flexible Removable screw terminal block, 0.25…2.5 mm² flexible with ferrule single conductor Removable screw terminal block, 0.2…1.5 mm² solid or flexible twin conductor Removable screw terminal block, 2 x 0.25…1 mm² flexible with ferrule without cable end, with bezel Removable screw terminal block, 2 x 0.5…1.5 mm² flexible with ferrule with cable end, with bezel |
| [Us] Rated Supply Voltage | 48…240 V AC – 15…10 % 48…240 V DC – 20…20 % |
| Synchronisation time between inputs | Unlimited |
|---|---|
| Type of start | Automatic/manual/monitored |
| Power consumption in W | 2.0 W 48…240 V DC |
| Power consumption in VA | 6.0 VA 48…240 V AC 50/60 Hz |
| Input protection type | Internal, electronic |
| safety outputs | 4 NO + 1 NC |
| safety inputs | 0 |
| Input compatibility | Normally closed circuit ISO 14119 XC limit switch ISO 14119 Mechanical contact ISO 14119 Normally closed circuit ISO 13850 |
| input terminal | Power supply |
| [Ie] rated operational current | 5 A AC-1 for normally open relay contact 3 A AC-15 for normally open relay contact 5 A DC-1 for normally open relay contact 3 A DC-13 for normally open relay contact 3 A AC-1 for normally closed relay contact 1 A AC-15 for normally closed relay contact 3 A DC-1 for normally closed relay contact 1 A DC-13 for normally closed relay contact |
| control outputs | 0 |
| [Ith] conventional free air thermal current | 6 A |
| Associated fuse rating | 10 A gG NO relay output circuit IEC 60947-1 |
| Minimum output current | 10 mA relay output |
| Minimum output voltage | 5 V relay output |
| Response time | 60 ms at 48…240 V AC/DC |
| [Ui] rated insulation voltage | 300 V 2)IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 4 kV II IEC 60947-1 |
| Local signalling | LED green power power ON LED red error error LED yellow state status LED yellow start1 start input LED yellow start2 start input |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 4.7 in (120 mm) |
| Height | 3.9 in (100 mm) |
| Width | 0.9 in (22.5 mm) |
| Net Weight | 0.441 lb(US) (0.200 kg) |