Ordering data
| Product type description |
AZM400Z-ST-I1-1P2P |
| Article number (order number) |
103003732 |
| EAN (European Article Number) |
4030661472591 |
| eCl@ss number, version 12.0 |
27-27-26-03 |
| eCl@ss number, version 11.0 |
27-27-26-03 |
| eCl@ss number, version 9.0 |
27-27-26-03 |
| ETIM number, version 7.0 |
EC002593 |
| ETIM number, version 6.0 |
EC002593 |
General data
| Standards |
EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-3 EN IEC 61508 |
| Coding |
Individual coding |
| Coding level according to EN ISO 14119 |
High |
| Working principle |
Magnetic field RFID |
| Frequency band RFID |
125 kHz |
| Transmitter output RFID, maximum |
-6 dBm |
| Housing material |
Light alloy die-casting |
| Reaction time, switching off safety outputs via actuator, maximum |
100 ms |
| Gross weight |
764 g |
Mechanical data
| Interlocking principle |
bistable |
| Mechanical lifetime, minimum |
1,000,000 Operations |
| Note (Mechanical lifetime) |
Which have a lateral force Ftrans = 100 N: 100.000 operations |
| Allowed distance interlock to actuator, minimum |
1 mm |
| Allowed distance interlock to actuator, maximum |
7 mm |
| Angular misalignment between solenoid interlock and actuator, maximum |
2 ° |
| Minimum distance devices |
30 mm |
| Holding force FZh in accordance with EN ISO 14119 |
10,000 N |
| Holding force Fmax, maximum |
13,000 N |
| Lateral force at bolt return, maximal (against locked door) |
300 N |
| Note (Lateral force at bolt return) |
Does not apply to emergency exit, Bowden cable and manual release |
| Type of the fixing screws |
2x M6 |
| Note (Type of the fixing screws) |
Property class min. 10.9 |
| Tightening torque of the screw |
8 Nm |
| Note |
The maximum tightening torque of the cover screw (cover triangle) is 0.55 Nm. |
Mechanical data – Connection technique
| Termination |
Connector M12, 8-pole, A-coded |
Ambient conditions
| Degree of protection |
IP66 IP67 |
| Ambient temperature |
-20 … +55 °C |
| Storage and transport temperature |
-40 … +85 °C |
| Relative humidity, maximum |
93 % |
| Note (Relative humidity) |
non-condensing non-icing |
| Resistance to vibrations |
10 … 150 Hz, amplitude 0.35 mm |
| Restistance to shock |
30 g / 11 ms |
| Protection class |
III |
| Permissible installation altitude above sea level, maximum |
2,000 m |
Ambient conditions – Insulation values
| Rated insulation voltage Ui |
32 VDC |
| Rated impulse withstand voltage Uimp |
0.8 kV |
| Overvoltage category |
III |
| Degree of pollution |
3 |
Electrical data
| Operating voltage |
24 VDC -15 % / +10 % (stabilised PELV power supply) |
| No-load supply current I0, typical |
100 mA |
| Operating current while bolt movement, peak |
600 mA / 100 ms |
| Rated operating voltage |
24 VDC |
| Required rated short-circuit current |
100 A |
| External wire and device fuse rating |
2 A gG |
| Time to readiness, maximum |
1,500 ms |
| Switching frequency, maximum |
0.3 Hz |
| Open / close cycle (motor), minimum |
3 s |
| Minimal average cycle time (with continuous operation) |
20 s |
| Utilisation category DC-12 |
24 VDC / 0.05 A |
| Electrical fuse rating, maximum |
2 A |
Electrical data – Control inputs Guard locking function
| Designation, Control inputs |
E1 und E2 (p-schaltend), E3 (n-schaltend) |
| Switching thresholds of the control inputs |
−3 V … 5 V (Low) 15 V … 30 V (High) |
| Classification ZVEI CB24I, Sink |
C0 |
| Classification ZVEI CB24I, Source |
C1 C2 C3 |
| Current consumption at 24V, minimum |
5 mA |
| Current consumption at 24V, maximum |
10 mA |
| Allowable discrepancy time (input), maximum |
10 s |
| Test pulse interval, maximum |
40 ms |
| Test pulse duration, maximum |
5 ms |
| Permissible residual drive current |
1.5 mA |
Electrical data – Safety digital outputs
| Designation, Safety outputs |
Y1 and Y2 |
| Design of control elements |
short-circuit proof, p-type |
| Voltage drop Ud, maximum |
2 V |
| Leakage current Ir, maximum |
0.5 mA |
| Voltage, Utilisation category DC-12 |
24 VDC |
| Current, Utilisation category DC-12 |
0.25 A |
| Voltage, Utilisation category DC-13 |
24 VDC |
| Current, Utilisation category DC-13 |
0.25 A |
| Test pulse interval, typical |
1000 ms |
| Test pulse duration, maximum |
0.5 ms |
| Classification ZVEI CB24I, Source |
C2 |
| Classification ZVEI CB24I, Sink |
C1 C2 |
Electrical data – Diagnostic outputs
| Designation, Diagnostic outputs |
OUT |
| Design of control elements |
short-circuit proof, p-type |
| Note |
The diagnostic output are not safety relevant outputs! |
| Voltage drop Ud, maximum |
2 V |
| Voltage, Utilisation category DC-12 |
24 VDC |
| Current, Utilisation category DC-12 |
0.05 A |
| Voltage, Utilisation category DC-13 |
24 VDC |
| Current, Utilisation category DC-13 |
0.05 A |
Accessory
| Recommendation (actuator) |
AZM400-B1 |