rig-well.com

Schmersal AZM400Z-ST-I1-1P2P Solenoid interlock 103003732

SKU: RW5085Y1Y2308

Ordering data

Product type description

AZM400Z-ST-I1-1P2P

Article number (order number)

103003732

EAN (European Article Number)

4030661472591

eCl@ss number, version 12.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 9.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

General data

Standards

EN ISO 13849-1

EN ISO 14119

EN IEC 60947-5-3

EN IEC 61508

Coding

Individual coding

Coding level according to EN ISO 14119

High

Working principle

Magnetic field

RFID

Frequency band RFID

125 kHz

Transmitter output RFID, maximum

-6 dBm

Housing material

Light alloy die-casting

Reaction time, switching off safety outputs via actuator, maximum

100 ms

Gross weight

764 g

Mechanical data

Interlocking principle

bistable

Mechanical lifetime, minimum

1,000,000 Operations

Note (Mechanical lifetime)

Which have a lateral force Ftrans = 100 N: 100.000 operations

Allowed distance interlock to actuator, minimum

1 mm

Allowed distance interlock to actuator, maximum

7 mm

Angular misalignment between solenoid interlock and actuator, maximum

2 °

Minimum distance devices

30 mm

Holding force FZh in accordance with EN ISO 14119

10,000 N

Holding force Fmax, maximum

13,000 N

Lateral force at bolt return, maximal (against locked door)

300 N

Note (Lateral force at bolt return)

Does not apply to emergency exit, Bowden cable and manual release

Type of the fixing screws

2x M6

Note (Type of the fixing screws)

Property class min. 10.9

Tightening torque of the screw

8 Nm

Note

The maximum tightening torque of the cover screw (cover triangle) is 0.55 Nm.

Mechanical data – Connection technique

Termination

Connector M12, 8-pole, A-coded

Ambient conditions

Degree of protection

IP66

IP67

Ambient temperature

-20 … +55 °C

Storage and transport temperature

-40 … +85 °C

Relative humidity, maximum

93 %

Note (Relative humidity)

non-condensing

non-icing

Resistance to vibrations

10 … 150 Hz, amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Protection class

III

Permissible installation altitude above sea level, maximum

2,000 m

Ambient conditions – Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

Operating voltage

24 VDC -15 % / +10 % (stabilised PELV power supply)

No-load supply current I0, typical

100 mA

Operating current while bolt movement, peak

600 mA / 100 ms

Rated operating voltage

24 VDC

Required rated short-circuit current

100 A

External wire and device fuse rating

2 A gG

Time to readiness, maximum

1,500 ms

Switching frequency, maximum

0.3 Hz

Open / close cycle (motor), minimum

3 s

Minimal average cycle time (with continuous operation)

20 s

Utilisation category DC-12

24 VDC / 0.05 A

Electrical fuse rating, maximum

2 A

Electrical data – Control inputs Guard locking function

Designation, Control inputs

E1 und E2 (p-schaltend), E3 (n-schaltend)

Switching thresholds of the control inputs

−3 V … 5 V (Low)

15 V … 30 V (High)

Classification ZVEI CB24I, Sink

C0

Classification ZVEI CB24I, Source

C1

C2

C3

Current consumption at 24V, minimum

5 mA

Current consumption at 24V, maximum

10 mA

Allowable discrepancy time (input), maximum

10 s

Test pulse interval, maximum

40 ms

Test pulse duration, maximum

5 ms

Permissible residual drive current

1.5 mA

Electrical data – Safety digital outputs

Designation, Safety outputs

Y1 and Y2

Design of control elements

short-circuit proof, p-type

Voltage drop Ud, maximum

2 V

Leakage current Ir, maximum

0.5 mA

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.25 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.25 A

Test pulse interval, typical

1000 ms

Test pulse duration, maximum

0.5 ms

Classification ZVEI CB24I, Source

C2

Classification ZVEI CB24I, Sink

C1

C2

Electrical data – Diagnostic outputs

Designation, Diagnostic outputs

OUT

Design of control elements

short-circuit proof, p-type

Note

The diagnostic output are not safety relevant outputs!

Voltage drop Ud, maximum

2 V

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.05 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.05 A

Accessory

Recommendation (actuator)

AZM400-B1

Weight 0.8 kg
error: