Side 1
| Mounting method | inserted, screwed |
|---|---|
| Degree of protection (EN IEC 60529) | IP65 |
Electrical data | Supply
| Operating voltage AC min. | 24 V |
|---|---|
| Operating voltage AC max. | 230 V |
| Operating voltage DC min. | 24 V |
| Operating voltage DC max. | 230 V |
| Current operating per contact max. | 4 A |
Diagnostics
| Status indication LED | green, red |
|---|
Installation
| Connection cross section max. | 1.5 mm² |
|---|
Installation | Connection
| Tightening torque | 0.4 Nm |
|---|---|
| Mounting set | M3x31 |
Device protection | Electrical
| Additional condition protection degree | locked, with screw connection, inserted |
|---|---|
| Pollution Degree | 2 |
| Rated surge voltage | 4 kV |
| Material group (IEC 60664-1) | III |
Mechanical data | Mounting data
| Mounting method | field-wireable, PG9 |
|---|---|
| Clamping range min. | 5 mm |
| Clamping range max. | 9.5 mm |
Environmental characteristics | Climatic
| Operating temperature min. | -20 °C |
|---|---|
| Operating temperature max. | 60 °C |
Important installation notes
| Note on bending radius | Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces. |
|---|---|
| Note on strain relief | Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties. |