Technical Data
- Valve function5/2-way, monostable
- Type of actuationElectric
- Construction width26 mm
- Standard nominal flow rate (standardised to DIN 1343)500 l/min
- pneumatic working portG1/8
- Operating voltageVia solenoid coil, must be ordered separately
- Operating pressure0.18 MPa … 0.8 MPa
- Operating pressure1.8 bar … 8 bar
- DesignPoppet seat
- Type of resetMechanical spring
- Approvalc UL us – Recognized (OL)
- Degree of protectionIP65
- Nominal size5 mm
- Grid dimension27 mm
- Exhaust-air functionWith flow control option
- Sealing principleSoft
- Mounting positionoptional
- Manual overrideDetenting
- Type of pilotingPilot actuated
- Flow directionNon-reversible
- Symbol00991035
- Overlapno
- Switching time off36 ms
- Switching time on8 ms
- Max. positive test pulse with 0 signal2200 µs
- Max. negative test pulse with 1 signal3700 µs
- Characteristic coil dataSee solenoid coil, to be ordered separately
- Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
- Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will always be required)
- Corrosion resistance class CRC1 – Low corrosion stress
- LABS (PWIS) conformityVDMA24364-B1/B2-L
- Storage temperature-20 °C … 60 °C
- Media temperature-10 °C … 60 °C
- Ambient temperature-5 °C … 40 °C
- Product weight270 g
- Electrical connectionVia F coil, to be ordered separately
- Type of mountingOn manifold rail With through-hole
- Pilot exhaust port 82M5
- Pneumatic connection, port 1G1/8
- Pneumatic connection, port 2G1/8
- Pneumatic connection, port 3G1/8
- Pneumatic connection, port 4G1/8
- Pneumatic connection, port 5G1/8
- Note on materialsRoHS-compliant
- Material sealsNBR TPE-U(PU)
- Material housingDie-cast aluminium