rig-well.com

ABB PSTX300-600-70 Softstarter 1SFA898114R7000

PSTX300-600-70 Softstarter – 300 A – 208 … 600 V AC
SKU: RWHD2072U5T2408

Dimensions

Product Net Width:
258 mm
Product Net Height:
470 mm
Product Net Depth / Length:
279 mm
Product Net Weight:
15.5 kg

Technical

Rated Operational Voltage:
208 … 600 V AC
Rated Control Supply Voltage (Us):
100 … 250 V AC
Rated Control Circuit Voltage (Uc):
24 V DC
Rated Frequency (f):
50/60 Hz
Main Circuit 50 / 60 Hz
Rated Operational Power – In-Line Connection (Pe):
(230 V) 90 kW
(400 V) 160 kW
(500 V) 200 kW
Rated Operational Current – In-Line Connection (Ie):
300 A
Rated Operational Power – Inside Delta Connection:
at 230 V 160 kW
at 400 V 257 kW
at 500 V 355 kW
Rated Operational Current – Inside Delta Connection:
515 A
Service Factor Percentage:
100 %
Overload Protection:
Built-in electronic overload protection
Integrated Electronic Overload:
Yes
Starting Capacity at Maximum Rated Current Ie:
4xIe for 10s
Ramp Time:
1 … 120 second [unit of time]
Initial Voltage During Start:
30 … 99 %
Step Down Voltage Special Ramp:
100 … 10 %
Current Limit Function:
1.5 … 7.5 xle
Switch for Inside Delta Connection:
Yes
Run Signal Relay:
Yes
By-pass Signal Relay:
Yes
Fault Signal Relay:
Yes
Overload Signal Relay:
Yes
Analog Outputs:
0…10 V, 0…20 mA, 4…20 mA
Signal Indication Ready to Start/Standby ON (LED):
Green
Signal Indication Running R (LED):
Green
Signal Indication Protection (LED):
Yellow
Signal Indication Fault (LED):
Red
Communication:
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type:
Main Circuit: Bars
Connecting Capacity Main Circuit:
Hole Diameter 10.2 mm
Connecting Capacity Control Circuit:
Rigid 1 x 2.5 mm²
Connecting Capacity Supply Circuit:
Rigid 1 x 2.5
Tightening Torque:
Main Circuit 25 N·m
Product Main Type:
PSTX300
Function:
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Protection Function:
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Warning Details:
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) – Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Technical UL/CSA

Horsepower Rating UL/CSA:
(200 … 208 V AC) Three Phase 100 Hp
(220 … 240 V AC) Three Phase 100 Hp
(440 … 480 V AC) Three Phase 250 Hp
(550 … 600 V AC) Three Phase 300 Hp
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
Tightening Torque UL/CSA:
Main Circuit 221.3

Environmental

Ambient Air Temperature:
Operation -25 … +60 °C
Storage -40 … +70 °C
Weight 18 kg
error: