working range:
papers with weights of 100 – 2,000 g/m2, plastic sheets and films up to 5 mm thick*, self-adhesive films, sheet metals up to 2 mm thick*, corrugated card, wafers, PCBs (*: material-dependent)
design:
cylindrical M18
particularities:
distance between transmitter and receiver can be selected
cable connection
means of measurement:
pulse operation with amplitude evaluation
transducer frequency:
200 kHz
blind zone:
7 mm in front of transmitter and receiver
operating voltage UB:
20 – 30 V d.c., reverse polarity protection
voltage ripple:
± 10 %
no-load current consumption:
≤ 50 mA
type of connection:
2 m PUR cable, 7 x 0.14 mm2
transmitter cable:
at the receiver: 1.2 m PUR cable, at the transmitter: 1 m PUR cable with M8 initiator plug