Electrical connection values
| Fuse | T10/F20 |
| Rated insulation voltage Ui | 250 V |
| Rated impulse voltage Uimp | 2.5 kV |
| Utilization category | |
| DC-13 | 24V 2A |
| AC-15 | 230V 4A |
| Switching voltage | min. 10 V |
| Switching current | |
| (at 24V) | min. 12 mA |
Mechanical values and environment
| Connection type | Tab connector 2.8×0.5 IEC760 |
| Number of monitoring contacts | 4 |
| Actuating directions | 4 |
| Storage temperature | -25 … 70 °C |
| Mechanical life | 1 x 10⁶ |
| Mounting cut-out | D22 (EN IEC 60947-5-1) |
| Switching principle | Changeover contact C, IEC 947-5-1 |
| Degree of protection | |
| on the front with bellows | IP65 |
| Ambient temperature | -25 … 65 °C |
| Material | |
| Housing thermoplastic | |
| Contact | Silver alloy |
| Bellows elastomer, black | |
| Switching lever stainless steel |