Ordering data
| Product type description |
AZM170-11ZRK-ST-2197 24VAC/DC |
| Article number (order number) |
101141425 |
| EAN (European Article Number) |
4030661121918 |
| eCl@ss number, version 12.0 |
27-27-26-03 |
| eCl@ss number, version 11.0 |
27-27-26-03 |
| eCl@ss number, version 9.0 |
27-27-26-03 |
| ETIM number, version 7.0 |
EC002593 |
| ETIM number, version 6.0 |
EC002593 |
Approvals – Standards
| Certificates |
cULus CCC |
General data
| Standards |
EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-1 |
| Coding level according to EN ISO 14119 |
Low |
| Working principle |
electromechanical |
| Housing material |
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| Gross weight |
295 g |
General data – Features
| Power to unlock |
Yes |
| Manual release |
Yes |
| Number of actuating directions |
2 |
| Number of auxiliary contacts |
1 |
| Number of safety contacts |
1 |
| Safety classification |
| Standards |
EN ISO 13849-1 |
| Performance Level, up to |
c |
| Category |
1 |
| B10D Normally-closed contact (NC) |
2,000,000 Operations |
| Note |
Electrical life on request. |
| B10D Normally-open contact (NO) |
1,000,000 Operations |
| Note |
at 10% Ie and ohmic load |
| Mission time |
20 Year(s) |
Safety classification – Safety outputs
| Note (B10D Normally open contact (NO)) |
at 10% Ie and ohmic load |
| Safety classification – Fault exclusion |
| Please note: |
Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. |
| Performance Level, up to |
d |
| Category |
3 |
| Note |
for 2-channel use and with suitable logic unit. |
| Mission time |
20 Year(s) |
Mechanical data
| Mechanical lifetime, minimum |
1,000,000 Operations |
| Holding force FZh in accordance with EN ISO 14119 |
1,000 N |
| Holding force Fmax, maximum |
1,300 N |
| Latching force |
30 N |
| Positive break travel |
11 mm |
| Positive break force per NC contact, minimum |
8.5 N |
| Positive break force, minimum |
8.5 N |
| Actuating speed, maximum |
2 m/s |
| Mounting |
Screws |
| Type of the fixing screws |
2x M4 |
| Tightening torque of the fastening screws for the housing cover, minimum |
0.7 Nm |
| Tightening torque of the fastening screws for the housing cover, maximum |
1 Nm |
| Note |
Torx T10 |
Mechanical data – Connection technique
| Connector position |
Centre |
| Termination |
Connector plug M12, 4-pole, (A-coding) IDC method of termination |
| Cable section, minimum |
0.75 mm² |
| Cable section, maximum |
1 mm² |
| Allowed type of cable |
flexible |
Mechanical data – Dimensions
| Length of sensor |
30 mm |
| Width of sensor |
108 mm |
| Height of sensor |
75.5 mm |
Ambient conditions
| Degree of protection |
IP67 |
| Ambient temperature |
-25 … +60 °C |
| Storage and transport temperature |
-25 … +85 °C |
| Note (Relative humidity) |
non-condensing non-icing |
| Protection class |
II |
| Permissible installation altitude above sea level, maximum |
2,000 m |
Ambient conditions – Insulation values
| Rated insulation voltage Ui |
60 V |
| Rated impulse withstand voltage Uimp |
0.8 kV |
| Overvoltage category |
III |
| Degree of pollution |
3 |
Electrical data
| Thermal test current |
4 A |
| Rated control voltage |
24 VAC/DC |
| Required rated short-circuit current |
1,000 A |
| Electrical power consumption, maximum |
12 W |
| Switching element |
1 NO contact, 1 NC contacts |
| Note (Switching element) |
Change-over contact with double break, type Zb or 2 NC contacts, with galvanically separated contact bridges |
| Switching principle |
slow action, positive break NC contact |
| Maximale Schalthäufigkeit |
1,000 /h |
| Material of the contacts, electrical |
Silver |
Electrical data – Magnet control
| Magnet switch-on time |
100 % |
| Test pulse duration, maximum |
5 ms |
| Test pulse interval, minimum |
50 ms |
Electrical data – Safety contacts
| Voltage, Utilisation category AC-15 |
230 VAC |
| Current, Utilisation category AC-15 |
4 A |
| Voltage, Utilisation category DC-13 |
24 VDC |
| Current, Utilisation category DC-13 |
4 A |
| Note, Utilisation category DC-13 |
Connector 4-pole |
Electrical data – Auxiliary contacts
| Voltage, Utilisation category AC-15 |
230 VAC |
| Current, Utilisation category AC-15 |
4 A |
| Voltage, Utilisation category DC-13 |
24 VDC |
| Current, Utilisation category DC-13 |
4 A |
| Note, Utilisation category DC-13 |
Connector 4-pin |