Schneider LC1D95M7

LC1D95M7C contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 220VAC 50/60Hz coil, open style
SKU: RW355Y1T

Specifications

Main
Range TeSys
Range of Product TeSys Deca
Product or Component Type Contactor
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-3
AC-3e
AC-4
AC-1
Poles description 3P
[Ue] rated operational voltage Power circuit <= 690 V AC 25…400 Hz
[Ie] rated operational current 95 A (at <140 °F (60 °C)) at <= 440 V AC-3 for power circuit
125 A (at <140 °F (60 °C)) at <= 1000 V AC-1 for power circuit
95 A (at <140 °F (60 °C)) at <= 440 V AC-3e for power circuit
[Uc] control circuit voltage 220 V AC 50/60 Hz
Complementary
Motor power kW 25 kW at 220…230 V AC 50 Hz (AC-3)
45 kW at 380…400 V AC 50 Hz (AC-3)
45 kW at 415…440 V AC 50 Hz (AC-3)
55 kW at 500 V AC 50 Hz (AC-3)
45 kW at 660…690 V AC 50 Hz (AC-3)
15 kW at 400 V AC 50 Hz (AC-4)
25 kW at 220…230 V AC 50 Hz (AC-3e)
45 kW at 380…400 V AC 50 Hz (AC-3e)
45 kW at 415…440 V AC 50 Hz (AC-3e)
55 kW at 500 V AC 50 Hz (AC-3e)
45 kW at 660…690 V AC 50 Hz (AC-3e)
Maximum Horse Power Rating 7.5 hp at 120 V AC 60 Hz for 1 phase motors
15 hp at 230/240 V AC 60 Hz for 1 phase motors
30 hp at 200/208 V AC 60 Hz for 3 phase motors
30 hp at 230/240 V AC 60 Hz for 3 phase motors
60 hp at 460/480 V AC 60 Hz for 3 phase motors
60 hp at 575/600 V AC 60 Hz for 3 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 140 °F (60 °C)) for signalling circuit
125 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity 1100 A at 440 V AC for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 1100 A 104 °F (40 °C) – 1 s for power circuit
800 A 104 °F (40 °C) – 10 s for power circuit
400 A 104 °F (40 °C) – 1 min for power circuit
135 A 104 °F (40 °C) – 10 min for power circuit
140 A – 100 ms for signalling circuit
120 A – 500 ms for signalling circuit
100 A – 1 s for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
200 A gG at <= 690 V coordination type 1 for power circuit
160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.8 mOhm – Ith 125 A 50 Hz for power circuit
Power dissipation per pole 12.5 W AC-1
7.2 W AC-3
7.2 W AC-3e
[Ui] rated insulation voltage Power circuit 1000 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Overvoltage category III
pollution degree 3
[Uimp] rated impulse withstand voltage 8 kV IEC 60947
Safety reliability level B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1
B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 4 Mcycles
Electrical durability 1.2 Mcycles 95 A AC-3
1.3 Mcycles 125 A AC-1
1.2 Mcycles 95 A AC-3e
Control circuit type AC 50/60 Hz standard
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.8…1.1 Uc (-40…131 °F (-40…55 °C)):operational AC 50 Hz
0.85…1.1 Uc (-40…131 °F (-40…55 °C)):operational AC 60 Hz
0.3…0.6 Uc (-40…158 °F (-40…70 °C)):drop-out AC 50/60 Hz
1…1.1 Uc (131…158 °F (55…70 °C)):operational AC 50/60 Hz
Inrush power in VA 245 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))
245 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA 26 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
26 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation 6…10 W at 50/60 Hz
Operating time 20…35 ms closing
6…20 ms opening
Maximum operating rate 3600 cyc/h at 60 °C
Connections – terminals Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end
Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: flexible without cable end
Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) – cable stiffness: flexible without cable end
Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: flexible with cable end
Power circuit: connector 2 0.006…0.02 in² (4…16 mm²) – cable stiffness: flexible with cable end
Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: solid without cable end
Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) – cable stiffness: solid without cable end
Tightening torque Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2
Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm
Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm)
Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting Support Rail
Plate
Environment
Standards EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
CSA C22.2 No 14
UL 60947-4-1
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
IEC 60335-1:Clause 30.2
Product Certifications CCC
UL
CB Scheme
CSA
CE
UKCA
Marine
EAC
IP degree of protection IP20 front face IEC 60529
Protective treatment THIEC 60068-2-30
Climatic withstand IACS E10 exposure to damp heat
Permissible ambient air temperature around the device -40…140 °F (-40…60 °C)
140…158 °F (60…70 °C) with derating
Operating altitude 0…9842.52 ft (0…3000 m)
Fire resistance 1562 °F (850 °C) IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open 2 Gn, 5…300 Hz)
Shocks contactor open 8 Gn for 11 ms)
Vibrations contactor closed 3 Gn, 5…300 Hz)
Shocks contactor closed 10 Gn for 11 ms)
Height 5.0000000000 in (127 mm)
Width 3.3 in (85 mm)
Depth 5.1 in (130 mm)
Product Weight 3.55 lb(US) (1.61 kg)
Weight 1.6 kg