Specifications
Range of Product | Altivar 12 |
---|---|
Product or Component Type | Variable speed drive |
Product Specific Application | Simple machine |
Mounting Mode | Cabinet mount |
Communication Port Protocol | Modbus |
Supply frequency | 50/60 Hz +/- 5 % |
[Us] rated supply voltage | 200…240 V – 15…10 % |
nominal output current | 4.2 A |
Motor power kW | 0.75 kW |
Maximum Horse Power Rating | 1 hp |
EMC filter | Integrated |
IP degree of protection | IP20 |
Maximum Horse Power Rating | 1 hp |
Discrete input number | 4 |
---|---|
Discrete output number | 2 |
Analogue input number | 1 |
Analogue output number | 1 |
Relay output number | 1 |
Physical interface | 2-wire RS 485 |
Connector Type | 1 RJ45 |
Continuous output current | 4.2 A 4 kHz |
Method of access | Server Modbus serial |
Speed drive output frequency | 0.5…400 Hz |
Speed range | 1…20 |
Sampling duration | 20 ms +/- 1 ms logic input 10 ms analogue input |
Linearity error | +/- 0.3 % of maximum value analogue input |
Frequency resolution | Analog input converter A/D, 10 bits Display unit 0.1 Hz |
Time constant | 20 ms +/- 1 ms for reference change |
Transmission Rate | 9.6 kbit/s 19.2 kbit/s 38.4 kbit/s |
Transmission frame | RTU |
Number of addresses | 1…247 |
Data format | 8 bits, configurable odd, even or no parity |
Communication service | Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/write multiple registers (23) 4/4 words Read device identification (43) |
Type of polarization | No impedance |
4 quadrant operation possible | False |
Asynchronous motor control profile | Quadratic voltage/frequency ratio Voltage/frequency ratio (V/f) Sensorless flux vector control |
Maximum output frequency | 4 kHz |
Transient overtorque | 150…170 % of nominal motor torque depending on drive rating and type of motor |
Acceleration and deceleration ramps | Linear from 0 to 999.9 s U S |
Motor slip compensation | Preset in factory Adjustable |
Switching frequency | 2…16 kHz adjustable 4…16 kHz with derating factor |
Nominal switching frequency | 4 kHz |
Braking to standstill | By DC injection |
Brake chopper integrated | False |
Line current | 10.2 A 100 V heavy duty) 8.5 A 120 V heavy duty) |
Maximum Input Current per Phase | 8.5 A |
Maximum output voltage | 240 V |
Apparent power | 2.0 kVA 240 V heavy duty) |
Maximum transient current | 6.3 A 60 s heavy duty) 6.9 A 2 s heavy duty) |
Network Frequency | 50-60 Hz |
Relative symmetric network frequency tolerance | 5 % |
Prospective line Isc | 1 kA |
Base load current at high overload | 4.2 A |
Power dissipation in W | Natural 44.0 W |
With safety function Safely Limited Speed (SLS) | False |
With safety function Safe brake management (SBC/SBT) | False |
With safety function Safe Operating Stop (SOS) | False |
With safety function Safe Position (SP) | False |
With safety function Safe programmable logic | False |
With safety function Safe Speed Monitor (SSM) | False |
With safety function Safe Stop 1 (SS1) | False |
With sft fct Safe Stop 2 (SS2) | False |
With safety function Safe torque off (STO) | False |
With safety function Safely Limited Position (SLP) | False |
With safety function Safe Direction (SDI) | False |
Protection type | Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t |
Tightening torque | 7.08 lbf.in (0.8 N.m) |
Insulation | Electrical between power and control |
Quantity per Set | Set of 1 |
Width | 2.8 in (72 mm) |
Height | 5.6 in (143 mm) |
Depth | 5.2 in (131.2 mm) |
Product Weight | 1.8 lb(US) (0.8 kg) |