| Supply voltage | 10 V DC … 30 V DC |
| Ripple | ≤ 10 Vpp 1) |
| Voltage drop | ≤ 2 V |
| Time delay before availability | ≤ 50 ms |
| Hysteresis | 3 % … 15 % 2) |
| Reproducibility | ≤ 2 % |
| Temperature drift (of Sr) | ± 10 % |
| Continuous current Ia | ≤ 200 mA |
| No load current | 12.5 mA |
| Cable gland clamping area | M20 1.5 |
| Wire size | ≤ 2.5 mm² |
| Short-circuit protection | ✔ |
| Power-up pulse protection | ✔ |
| Shock and vibration resistance | 30 g, 11 ms / 10 … 55 Hz, 1 mm |
| Ambient operating temperature | –25 °C … +85 °C |
| Ambient temperature, storage | –40 °C … +85 °C |
| Housing material | Plastic, PA 66 |
| Sensing face material | Plastic, PA 66 |
| Tightening torque, max. | 1.8 Nm |
| Protection class | II 3) |
| UL File No. | E348498 |
| Housing | Rectangular |
| Housing | Standard design |
| Dimensions (W x H x D) | 40 mm x 40 mm x 118 mm |
| Sensing range Sn | 20 mm |
| Safe sensing range Sa | 16.2 mm |
| Installation type | Flush |
| Switching frequency | 150 Hz |
| Connection type | Cable gland |
| Switching output | PNP |
| Switching output detail | PNP |
| Output function | Complementary |
| Electrical wiring | DC 4-wire |
| Enclosure rating | IP67, IP68, IP69K |
| Special applications | Difficult application conditions |
| Unit weight | 0.218 Kilograms |
| Net unit weight | 0.218 Kilograms |
| Unit volume | 313.875 Cubic Centimetres (cm³) |
| Country of origin | Malaysia |
| EAN | 4047084363634 |