rig-well.com

ABB OT40F4N2 (1SCA104932R1001) Switch-Disconnector

4-pole, front operated, base mounted, DIN-rail mountable switch-diconnector / non-fusible diconnect switch with protected clamp terminals, handle and shaft are not included

JG-200Y

Dimensions

Product Net Width:
48 mm
Product Net Height:
68 mm
Product Net Depth / Length:
56 mm
Product Net Weight:
0.125 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
67 mm
Package Level 1 Depth / Length:
79 mm
Package Level 1 Height:
61 mm
Package Level 1 Gross Weight:
0.14 kg
Package Level 1 EAN:
6417019390727

Technical

Cable Cross-Section:
Cu 0.75 … 10 mm²
Connecting Capacity Main Circuit:
Flexible with Ferrule 1x Cu 0.75…4 mm²
Solid 1x Cu 0.75…6 mm²
Flexible 1x Cu 0.75…10 mm²
Stranded 1x Cu 0.75…10 mm²
Conventional Free-air Thermal Current (Ith):
Θ = 40 °C 40 A
Conventional Thermal Current (Ithe):
Fully Enclosed 40 A
Degree of Protection:
Front IP20
Distance Between Phases:
Standard
Fourth Pole Position:
Right Side
Fourth Pole Type:
Switched – Simultaneous Function
Handle Type:
Knob
Handle and shaft not included
Mechanical Durability:
20000
Mounting Type:
Base mounting
Number of Poles:
4P
Operating Mode:
Front operated
Pollution Degree:
3
Position of Line Terminals:
Top In – Bottom Out
Bottom In – Top Out
Power Loss:
at Rated Operating Conditions per Pole 1.6 W
Rated Conditional Short-Circuit Current (Inc):
(40 A fuse, ≤415V) 50 kA
(25 A fuse, 690 V) 50 kA
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Insulation Voltage (Ui):
acc. to IEC/EN 60664-1 750 V
Rated Operational Current AC-21A (Ie):
(380 … 415 V) 40 A
(500 V) 40 A
(690 V) 40 A
Rated Operational Current AC-22A (Ie):
(380 … 415 V) 40 A
(500 V) 40 A
(690 V) 40 A
Rated Operational Current AC-23A (Ie):
(380 … 415 V) 23 A
(500 V) 23 A
(690 V) 12 A
Rated Operational Power AC-23A (Pe):
(220 … 240 V) 5.5 kW
(400 … 415 V) 11 kW
(500 V) 11 kW
(690 V) 11 kW
Rated Operational Voltage:
Main Circuit 750 V
Rated Short-Circuit Making Capacity (Icm):
(690 V) 0.71 kA
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 0.5 kA
Recommended Screw Driver:
Main Circuit Pozidriv 2
Special Functions:
No
Standards:
IEC 60947-3 / UL 508 / CSA C22.2 No. 14
Switches Operating Mechanism:
Mechanism on Top of the Switch
Terminal Type:
Screw Terminals
Tightening Torque:
acc. IEC 60947-1 0.8 N·m
Wire Stripping Length:
Main Circuit 9-10 mm

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
600 V
Ampere Rating:
40 A
Horsepower Rating UL/CSA:
(110 … 120 V AC) Single Phase 2 Hp
(240 V AC) Single Phase 5 Hp
(440 … 480 V AC) Single Phase 10 Hp
(550 … 600 V AC) Single Phase 15 Hp
(220 … 240 V AC) Three Phase 10 Hp
(440 … 480 V AC) Three Phase 20 Hp
(550 … 600 V AC) Three Phase 25 Hp
Wire Stripping Length:
Main Circuit 9-10 mm
Recommended Screw Driver:
Main Circuit Pozidriv 2
Tightening Torque:
acc. IEC 60947-1 0.8 N·m
Tightening Torque UL/CSA:
7 in·lb
Weight 0.15 kg
error: